Krstić-Furundžić, Aleksandra

Link to this page

Authority KeyName Variants
orcid::0000-0001-9126-9336
  • Krstić-Furundžić, Aleksandra (4)
Projects

Author's Bibliography

Dataset on the energy performance of atrium type hotel buildings

Vujošević, Milica; Krstić-Furundžić, Aleksandra

(Elsevier, 2018)

TY  - JOUR
AU  - Vujošević, Milica
AU  - Krstić-Furundžić, Aleksandra
PY  - 2018
UR  - https://raumplan.iaus.ac.rs/handle/123456789/303
AB  - The data presented in this article are related to the research article entitled “The Influence of Atrium on Energy Performance of Hotel Building” (Vujosevic and Krstic-Furundzic, 2017) [1], which describes the annual energy performance of atrium type hotel building in Belgrade climate conditions, with the objective to present the impact of the atrium on the hotel building's energy demands for space heating and cooling. This dataset is made publicly available to show energy performance of selected hotel design alternatives, in order to enable extended analyzes of these data for other researchers.
PB  - Elsevier
T2  - Data in Brief
T1  - Dataset on the energy performance of atrium type hotel buildings
VL  - 17
SP  - 1336
EP  - 1347
DO  - 10.1016/j.dib.2018.01.040
ER  - 
@article{
author = "Vujošević, Milica and Krstić-Furundžić, Aleksandra",
year = "2018",
abstract = "The data presented in this article are related to the research article entitled “The Influence of Atrium on Energy Performance of Hotel Building” (Vujosevic and Krstic-Furundzic, 2017) [1], which describes the annual energy performance of atrium type hotel building in Belgrade climate conditions, with the objective to present the impact of the atrium on the hotel building's energy demands for space heating and cooling. This dataset is made publicly available to show energy performance of selected hotel design alternatives, in order to enable extended analyzes of these data for other researchers.",
publisher = "Elsevier",
journal = "Data in Brief",
title = "Dataset on the energy performance of atrium type hotel buildings",
volume = "17",
pages = "1336-1347",
doi = "10.1016/j.dib.2018.01.040"
}
Vujošević, M.,& Krstić-Furundžić, A.. (2018). Dataset on the energy performance of atrium type hotel buildings. in Data in Brief
Elsevier., 17, 1336-1347.
https://doi.org/10.1016/j.dib.2018.01.040
Vujošević M, Krstić-Furundžić A. Dataset on the energy performance of atrium type hotel buildings. in Data in Brief. 2018;17:1336-1347.
doi:10.1016/j.dib.2018.01.040 .
Vujošević, Milica, Krstić-Furundžić, Aleksandra, "Dataset on the energy performance of atrium type hotel buildings" in Data in Brief, 17 (2018):1336-1347,
https://doi.org/10.1016/j.dib.2018.01.040 . .
3
2
3

The influence of atrium on energy performance of hotel building

Vujošević, Milica; Krstić-Furundžić, Aleksandra

(Lausanne : Elsevier Science, 2017)

TY  - JOUR
AU  - Vujošević, Milica
AU  - Krstić-Furundžić, Aleksandra
PY  - 2017
UR  - https://raumplan.iaus.ac.rs/handle/123456789/320
AB  - This paper analyses annual energy performance of atrium type hotel building in Belgrade. The objective is to examine the impact of the atrium on the hotel building's energy demands for space heating and cooling. Integrated approach through numerical simulations that include Belgrade climate data and thermal comfort parameters, indicates an optimal model of hotel building with atrium for this area. Building energy simulation is carried out using EnergyPlus simulation engine, as a basic tool in the process of building energy optimization. The methodological approach includes the creation of a hypothetical model of an atrium type hotel building, numerical simulation of energy performances of several design alternatives of the hotel building with atrium, and comparative analysis of the obtained results. The main task of analysis is to change certain parameters in the particular model (for example, building structure, orientation, etc.) and to observe how the changes influence energy performance of the building. The goal of this research is to show that the atrium contributes to the heating and cooling energy savings in the rest of the building, but also that the atrium itself demands a lot of energy for its air-conditioning. The most sustainable solution should be to cover energy demands for atrium by using the renewable energy sources. In this case, the atrium can contribute to the energy efficiency of the hotel building in Belgrade climatic conditions, thus reducing its negative impact on the environment.
PB  - Lausanne : Elsevier Science
T2  - Energy and Buildings
T1  - The influence of atrium on energy performance of hotel building
VL  - 156
SP  - 140
EP  - 150
DO  - 10.1016/j.enbuild.2017.09.068
ER  - 
@article{
author = "Vujošević, Milica and Krstić-Furundžić, Aleksandra",
year = "2017",
abstract = "This paper analyses annual energy performance of atrium type hotel building in Belgrade. The objective is to examine the impact of the atrium on the hotel building's energy demands for space heating and cooling. Integrated approach through numerical simulations that include Belgrade climate data and thermal comfort parameters, indicates an optimal model of hotel building with atrium for this area. Building energy simulation is carried out using EnergyPlus simulation engine, as a basic tool in the process of building energy optimization. The methodological approach includes the creation of a hypothetical model of an atrium type hotel building, numerical simulation of energy performances of several design alternatives of the hotel building with atrium, and comparative analysis of the obtained results. The main task of analysis is to change certain parameters in the particular model (for example, building structure, orientation, etc.) and to observe how the changes influence energy performance of the building. The goal of this research is to show that the atrium contributes to the heating and cooling energy savings in the rest of the building, but also that the atrium itself demands a lot of energy for its air-conditioning. The most sustainable solution should be to cover energy demands for atrium by using the renewable energy sources. In this case, the atrium can contribute to the energy efficiency of the hotel building in Belgrade climatic conditions, thus reducing its negative impact on the environment.",
publisher = "Lausanne : Elsevier Science",
journal = "Energy and Buildings",
title = "The influence of atrium on energy performance of hotel building",
volume = "156",
pages = "140-150",
doi = "10.1016/j.enbuild.2017.09.068"
}
Vujošević, M.,& Krstić-Furundžić, A.. (2017). The influence of atrium on energy performance of hotel building. in Energy and Buildings
Lausanne : Elsevier Science., 156, 140-150.
https://doi.org/10.1016/j.enbuild.2017.09.068
Vujošević M, Krstić-Furundžić A. The influence of atrium on energy performance of hotel building. in Energy and Buildings. 2017;156:140-150.
doi:10.1016/j.enbuild.2017.09.068 .
Vujošević, Milica, Krstić-Furundžić, Aleksandra, "The influence of atrium on energy performance of hotel building" in Energy and Buildings, 156 (2017):140-150,
https://doi.org/10.1016/j.enbuild.2017.09.068 . .
36
15
37

The influence of atrium on energy performance of hotel building

Vujošević, Milica; Krstić-Furundžić, Aleksandra

(Elsevier Science Sa, Lausanne, 2017)

TY  - JOUR
AU  - Vujošević, Milica
AU  - Krstić-Furundžić, Aleksandra
PY  - 2017
UR  - https://raumplan.iaus.ac.rs/handle/123456789/299
AB  - This paper analyses annual energy performance of atrium type hotel building in Belgrade. The objective is to examine the impact of the atrium on the hotel building's energy demands for space heating and cooling. Integrated approach through numerical simulations that include Belgrade climate data and thermal comfort parameters, indicates an optimal model of hotel building with atrium for this area. Building energy simulation is carried out using EnergyPlus simulation engine, as a basic tool in the process of building energy optimization. The methodological approach includes the creation of a hypothetical model of an atrium type hotel building, numerical simulation of energy performances of several design alternatives of the hotel building with atrium, and comparative analysis of the obtained results. The main task of analysis is to change certain parameters in the particular model (for example, building structure, orientation, etc.) and to observe how the changes influence energy performance of the building. The goal of this research is to show that the atrium contributes to the heating and cooling energy savings in the rest of the building, but also that the atrium itself demands a lot of energy for its air-conditioning. The most sustainable solution should be to cover energy demands for atrium by using the renewable energy sources. In this case, the atrium can contribute to the energy efficiency of the hotel building in Belgrade climatic conditions, thus reducing its negative impact on the environment.
PB  - Elsevier Science Sa, Lausanne
T2  - Energy and Buildings
T1  - The influence of atrium on energy performance of hotel building
VL  - 156
SP  - 140
EP  - 150
DO  - 10.1016/j.enbuild.2017.09.068
ER  - 
@article{
author = "Vujošević, Milica and Krstić-Furundžić, Aleksandra",
year = "2017",
abstract = "This paper analyses annual energy performance of atrium type hotel building in Belgrade. The objective is to examine the impact of the atrium on the hotel building's energy demands for space heating and cooling. Integrated approach through numerical simulations that include Belgrade climate data and thermal comfort parameters, indicates an optimal model of hotel building with atrium for this area. Building energy simulation is carried out using EnergyPlus simulation engine, as a basic tool in the process of building energy optimization. The methodological approach includes the creation of a hypothetical model of an atrium type hotel building, numerical simulation of energy performances of several design alternatives of the hotel building with atrium, and comparative analysis of the obtained results. The main task of analysis is to change certain parameters in the particular model (for example, building structure, orientation, etc.) and to observe how the changes influence energy performance of the building. The goal of this research is to show that the atrium contributes to the heating and cooling energy savings in the rest of the building, but also that the atrium itself demands a lot of energy for its air-conditioning. The most sustainable solution should be to cover energy demands for atrium by using the renewable energy sources. In this case, the atrium can contribute to the energy efficiency of the hotel building in Belgrade climatic conditions, thus reducing its negative impact on the environment.",
publisher = "Elsevier Science Sa, Lausanne",
journal = "Energy and Buildings",
title = "The influence of atrium on energy performance of hotel building",
volume = "156",
pages = "140-150",
doi = "10.1016/j.enbuild.2017.09.068"
}
Vujošević, M.,& Krstić-Furundžić, A.. (2017). The influence of atrium on energy performance of hotel building. in Energy and Buildings
Elsevier Science Sa, Lausanne., 156, 140-150.
https://doi.org/10.1016/j.enbuild.2017.09.068
Vujošević M, Krstić-Furundžić A. The influence of atrium on energy performance of hotel building. in Energy and Buildings. 2017;156:140-150.
doi:10.1016/j.enbuild.2017.09.068 .
Vujošević, Milica, Krstić-Furundžić, Aleksandra, "The influence of atrium on energy performance of hotel building" in Energy and Buildings, 156 (2017):140-150,
https://doi.org/10.1016/j.enbuild.2017.09.068 . .
36
15
37

Daylight performance of adapted industrial buildings

Stojković, Milena; Pucar, Mila; Krstić-Furundžić, Aleksandra

(Univerzitet u Nišu, 2016)

TY  - JOUR
AU  - Stojković, Milena
AU  - Pucar, Mila
AU  - Krstić-Furundžić, Aleksandra
PY  - 2016
UR  - https://raumplan.iaus.ac.rs/handle/123456789/276
AB  - This paper assesses the potential of historical industrial buildings to be reused as office spaces. Belgrade’s industrial heritage has been classified according to the criteria that influence visual comfort, including glazing area, floor depth, and orientation. Daylight performance of two representative buildings has been analyzed using daylight factor, point in time illuminance and spatial daylight autonomy. Potential improvement strategies that would not have a negative impact on the historical character of buildings have then been discussed. Further studies include increased internal surface reflectance and introduction of roof-lights. The impact of roof-lights on the annual cooling and heating load has been addressed in parallel. Since LEED is the dominant sustainability assessment tool in Serbia, preliminary compliance with LEED v4 Daylight credit has been assessed for all options. The methodology and findings can be applied to a wide range of industrial buildings in similar climatic conditions.
AB  - U radu je analizirana prenamena industrijskih objekata izgrađenih pre Drugog svetskog rata u poslovne. Industrijsko nasleđe Beograda je klasifikovano prema kriterijuma koji utiču na vizuelni komfor, uključujući veličinu prozora, dubinu osnove i orijentaciju objekata. Količina prirodne svetlosti je analizirana korišćenjem faktora dnevne osvetljenosti (daylight factor), nivoa osvetljenosti (point in time illuminance) i prostorne autonomije dnevne svetlosti (spatial daylight autonomy). Nakon analiza, razmatrane su potencijalne strategije za unapređenje nivoa osvetljenosti koje ne bi imale negativan uticaj na istorijski karakter zgrada. Dalje analize uključuju povećanje vrednosti refleksije površina prostorije i uvođenje krovnih prozora. Uticaj krovnih prozora na godišnju potrebnu energiju za grejanje i hlađenje objekata je takođe razmatrano. LEED je dominantan program za sertifikaciju poslovnih zgrada u Srbiji. Stoga, rad uključuje preliminarane analize svih opcija za usklađenost sa zahtevima LEED v4 kredita “Prirodno osvetljenje”. Metodologija i zaključci ovog istraživanja mogu se primeniti na širok spektar industrijskih objekata u sličnim klimatskim uslovima.
PB  - Univerzitet u Nišu
T2  - Facta universitatis - series: Architecture and Civil Engineering
T1  - Daylight performance of adapted industrial buildings
T1  - Prirodno osvetljenje u adaptiranim industrijskim objektima
VL  - 14
IS  - 1
SP  - 59
EP  - 74
DO  - 10.2298/FUACE1601059S
ER  - 
@article{
author = "Stojković, Milena and Pucar, Mila and Krstić-Furundžić, Aleksandra",
year = "2016",
abstract = "This paper assesses the potential of historical industrial buildings to be reused as office spaces. Belgrade’s industrial heritage has been classified according to the criteria that influence visual comfort, including glazing area, floor depth, and orientation. Daylight performance of two representative buildings has been analyzed using daylight factor, point in time illuminance and spatial daylight autonomy. Potential improvement strategies that would not have a negative impact on the historical character of buildings have then been discussed. Further studies include increased internal surface reflectance and introduction of roof-lights. The impact of roof-lights on the annual cooling and heating load has been addressed in parallel. Since LEED is the dominant sustainability assessment tool in Serbia, preliminary compliance with LEED v4 Daylight credit has been assessed for all options. The methodology and findings can be applied to a wide range of industrial buildings in similar climatic conditions., U radu je analizirana prenamena industrijskih objekata izgrađenih pre Drugog svetskog rata u poslovne. Industrijsko nasleđe Beograda je klasifikovano prema kriterijuma koji utiču na vizuelni komfor, uključujući veličinu prozora, dubinu osnove i orijentaciju objekata. Količina prirodne svetlosti je analizirana korišćenjem faktora dnevne osvetljenosti (daylight factor), nivoa osvetljenosti (point in time illuminance) i prostorne autonomije dnevne svetlosti (spatial daylight autonomy). Nakon analiza, razmatrane su potencijalne strategije za unapređenje nivoa osvetljenosti koje ne bi imale negativan uticaj na istorijski karakter zgrada. Dalje analize uključuju povećanje vrednosti refleksije površina prostorije i uvođenje krovnih prozora. Uticaj krovnih prozora na godišnju potrebnu energiju za grejanje i hlađenje objekata je takođe razmatrano. LEED je dominantan program za sertifikaciju poslovnih zgrada u Srbiji. Stoga, rad uključuje preliminarane analize svih opcija za usklađenost sa zahtevima LEED v4 kredita “Prirodno osvetljenje”. Metodologija i zaključci ovog istraživanja mogu se primeniti na širok spektar industrijskih objekata u sličnim klimatskim uslovima.",
publisher = "Univerzitet u Nišu",
journal = "Facta universitatis - series: Architecture and Civil Engineering",
title = "Daylight performance of adapted industrial buildings, Prirodno osvetljenje u adaptiranim industrijskim objektima",
volume = "14",
number = "1",
pages = "59-74",
doi = "10.2298/FUACE1601059S"
}
Stojković, M., Pucar, M.,& Krstić-Furundžić, A.. (2016). Daylight performance of adapted industrial buildings. in Facta universitatis - series: Architecture and Civil Engineering
Univerzitet u Nišu., 14(1), 59-74.
https://doi.org/10.2298/FUACE1601059S
Stojković M, Pucar M, Krstić-Furundžić A. Daylight performance of adapted industrial buildings. in Facta universitatis - series: Architecture and Civil Engineering. 2016;14(1):59-74.
doi:10.2298/FUACE1601059S .
Stojković, Milena, Pucar, Mila, Krstić-Furundžić, Aleksandra, "Daylight performance of adapted industrial buildings" in Facta universitatis - series: Architecture and Civil Engineering, 14, no. 1 (2016):59-74,
https://doi.org/10.2298/FUACE1601059S . .
2